272 research outputs found

    Chromatographic Separation Apparatus

    Get PDF
    An apparatus for the monitoring of a column chromatography separation process includes a segmented column with a seal positioned at the joint defined by the segments of the column. A connector is provided for connecting the segments of the column together. The apparatus further includes a sensor for monitoring an analyte in an eluant within a separation zone of the column. The sensor includes a mesh grid made of optical fibers or metal wires which is placed so as to extend through the separation zone of the column. The metal wires or optical fibers extend through the seal of the joint in the segmented column and connect to signal processing and data analysis equipment for purposes of monitoring the movements and concentration of an analyte in an eluant at various locations within the column. Certain segments of the optical fibers or metal wires which make up the mesh grid are coated so as to be desensitized and other segments are uncoated for sensing the analyte. This provides an effective apparatus to monitor in detail the cross-section of a column chromatography process in-situ

    Lattice sieving and trial division

    Get PDF
    Reports on work in progress on our new implementation of the relation collection stage of the general number field sieve integer factoring algorithm. Our experiments indicate that we have achieved a substantial speed-up compared to other implementations that are reported in the literature. The main improvements are a new lattice sieving technique and a trial division method that is based on lattice sieving in a hash table. This also allows us to collect triple and quadruple large prime relations in an efficient manner. Furthermore, we show how the computation can efficiently be shared among multiple processors in a high-bandwidth environmen

    Utility of Two iPhone Device Apps in Assessing Heart Rate at Rest and During Activity

    Get PDF
    Heart rate (HR) is a critical physiological variable used for prescribing exercise, assessing fitness level and tracking fitness improvements. Electrocardiography (ECG) stands as the criterion measure of HR. While recent development of HR-detecting mobile device applications (apps) has made evaluating HR more convenient; their degree of accuracy is unknown. Therefore, the purpose of this current study was to examine the accuracy and reliability of two-iPhone applications to detect HR at rest and during low-intensity exercise conditions. Eighteen female and 22 male subjects (26 + 9.5 yrs) were prepped for simultaneous detection of HR via three methods: ECG and two HR-detecting apps. App 1, a camera-based app called Azumio Instant Heart Rate (CAM), was used by placement of a finger over the camera lens of the mobile device. App 2, a microphone-based app called Heart Monitor by Bluespark, was employed via placement of an external microphone over the radial pulse. The participants underwent a series of 5-minute stages: seated rest followed by cycle then treadmill walking at low intensities. HR was recorded concurrently, at several time intervals from the three methods once a steady-state HR was reached. The means of the three devices were compared via ANOVA with the significance level set, a priori, at 0.05. Correlation analysis was employed to investigate relationships between the apps and ECG. No statistical difference was found between the CAM and ECG HR (p \u3e 0.05) during the resting and cycle stages. However, during the treadmill phase, there was a significant difference (p = 0.018) between CAM and ECG. Nevertheless, there was a significant (p \u3c 0.05), positive correlation between CAM and ECG under the resting, cycle and treadmill conditions (r = .966, r = .984, r = .877, respectively). Significant differences (p \u3c 0.05) were found for each condition when comparing ECG and MIC HR. Data also revealed poor correlations (p \u3e 0.05; r between -.004 and -.136) between MIC and ECG. The utility of CAM and MIC-based apps to detect HR remains in question as evidence appears to indicate exercise mode and app specificity. Caution should be shown when using these devices. The CAM-based app may accurately detect HR during resting and seated cycling but not during treadmill activity. The MIC-based app is not recommended for use in any condition. Of note, statistical significance may not mitigate usefulness when considering the accuracy of palpation. Additional research is necessary

    Inhibition of Ī±vĪ²5 Integrin Attenuates Vascular Permeability and Protects against Renal Ischemia-Reperfusion Injury

    Get PDF
    Ischemia-reperfusion injury (IRI) is a leading cause of AKI. This common clinical complication lacks effective therapies and can lead to the development of CKD. The Ī±vĪ²5 integrin may have an important role in acute injury, including septic shock and acute lung injury. To examine its function in AKI, we utilized a specific function-blocking antibody to inhibit Ī±vĪ²5 in a rat model of renal IRI. Pretreatment with this anti-Ī±vĪ²5 antibody significantly reduced serum creatinine levels, diminished renal damage detected by histopathologic evaluation, and decreased levels of injury biomarkers. Notably, therapeutic treatment with the Ī±vĪ²5 antibody 8 hours after IRI also provided protection from injury. Global gene expression profiling of post-ischemic kidneys showed that Ī±vĪ²5 inhibition affected established injury markers and induced pathway alterations previously shown to be protective. Intravital imaging of post-ischemic kidneys revealed reduced vascular leak with Ī±vĪ²5 antibody treatment. Immunostaining for Ī±vĪ²5 in the kidney detected evident expression in perivascular cells, with negligible expression in the endothelium. Studies in a three-dimensional microfluidics system identified a pericyte-dependent role for Ī±vĪ²5 in modulating vascular leak. Additional studies showed Ī±vĪ²5 functions in the adhesion and migration of kidney pericytes in vitro Initial studies monitoring renal blood flow after IRI did not find significant effects with Ī±vĪ²5 inhibition; however, future studies should explore the contribution of vasomotor effects. These studies identify a role for Ī±vĪ²5 in modulating injury-induced renal vascular leak, possibly through effects on pericyte adhesion and migration, and reveal Ī±vĪ²5 inhibition as a promising therapeutic strategy for AKI

    Benign Conduction Abnormalities in Response to Acute, Moderately-High, Simulated Altitude Exposure

    Get PDF
    Acclimatization to altitude can improve endurance performance above levels achieved solely by training at sea level. There is natural limitation in the applicability of employing terrestrial altitude training ā€“ namely proximity. A simple, non-cumbersome method of simulating altitude is desirable to many types of endurance athletes. The Alto2Lab (Pharma Pacific Inc.), consisting of primarily a breathing tube and silo stack, has shown some potential in this role. There is a lack of evidence regarding whether simulated altitude exposure triggers abnormal cardiovascular responses. The aim of this study was to provide initial evidence of cardiac changes associated with usage patterns that follow distributor guidelines. Twenty-five participants (mean age 29 Ā± 10.7; 16 males; 9 females) volunteered for the study. Subjects underwent a baseline ECG recording followed by ECG recording during sham (4-5 mins), hypoxia (~6 mins), and recovery (3-4 mins) phases. The sham phase consisted of subjects breathing normoxive air through a foam-filled silo system. The sham stack mimicked the look and feel of the silo system used to produce hypoxia with the difference being a single, soda lime-filled silo. A recovery phase followed hypoxia. Pulse oximetry (SpO2) was used to assess oxygen saturation. Cochranā€™s Q was employed to test the frequencies of responses across the phases. An independent, blinded, experienced clinician (DK) analyzed the recordings. Two subjects were removed from the final analysis (inability to finish the protocol, baseline right bundle branch block). All subjects demonstrated an increase in heart rate (mean = +16.8 Ā± 8.0) during the hypoxia (mean oxygen saturation = 82 Ā± 4.1%) phase. No ECG ischemic changes were seen across any of the phases. Benign conduction abnormalities (sinus arrhythmia = 9; junctional rhythms = 4) occurred with some regularity during hypoxia. These abnormalities occurred with less frequency during the sham and recovery phases. It is possible that an altered breathing pattern or an inadequate washout period between phases might account for these findings. Overall, there was no significant relationship between the heart response and phase (p = .375). While the Alto2Lab did not produce any ECG changes indicative of an ischemic response, the present study used a small sample of healthy, recreationally-active participants. A larger study employing patients among higher risk categories would provide data that is not currently present in the literature and to which this trial cannot speak

    Alterations in vascular function in primary aldosteronism - a cardiovascular magnetic resonance imaging study

    Get PDF
    Introduction: Excess aldosterone is associated with increased cardiovascular risk. Aldosterone has a permissive effect on vascular fibrosis. Cardiovascular magnetic resonance imaging (CMR) allows study of vascular function by measuring aortic distensibility. We compared aortic distensibility in primary aldosteronism (PA), essential hypertension (EH) and normal controls and explored the relationship between aortic distensibility and pulse wave velocity (PWV).<p></p> Methods: We studied PA (n=14) and EH (n=33) subjects and age-matched healthy controls (n=17) with CMR, including measurement of aortic distensibility, and measured PWV using applanation tonometry. At recruitment, PA and EH patients had similar blood pressure and left ventricular mass.<p></p> Results: Subjects with PA had significantly lower aortic distensibilty and higher PWV compared to EH and healthy controls. These changes were independent of other factors associated with reduced aortic distensibility, including aging. There was a significant relationship between increasing aortic stiffness and age in keeping with physical and vascular aging. As expected, aortic distensibility and PWV were closely correlated.<p></p> Conclusion: These results demonstrate that PA patients display increased arterial stiffness compared to EH, independent of vascular aging. The implication is that aldosterone invokes functional impairment of arterial function. The long-term implications of arterial stiffening in aldosterone excess require further study.<p></p&gt

    Nuclear receptors in vascular biology

    Get PDF
    Nuclear receptors sense a wide range of steroids and hormones (estrogens, progesterone, androgens, glucocorticoid, and mineralocorticoid), vitamins (A and D), lipid metabolites, carbohydrates, and xenobiotics. In response to these diverse but critically important mediators, nuclear receptors regulate the homeostatic control of lipids, carbohydrate, cholesterol, and xenobiotic drug metabolism, inflammation, cell differentiation and development, including vascular development. The nuclear receptor family is one of the most important groups of signaling molecules in the body and as such represent some of the most important established and emerging clinical and therapeutic targets. This review will highlight some of the recent trends in nuclear receptor biology related to vascular biology

    Validation of reference genes for quantitative RT-qPCR studies of gene expression in Atlantic cod (Gadus morhua l.) during temperature stress

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>One important physiological response to environmental stress in animals is change in gene expression. To obtain reliable data from gene expression studies using RT-qPCR it is important to evaluate a set of possible reference genes as normalizers for expression. The expression of these candidate genes should be analyzed in the relevant tissues during normal and stressed situations. To find suitable reference genes it was crucial that the genes were stably expressed also during a situation of physiological stress. For poikilotermic animals like cod, changes in temperature are normal, but if the changes are faster than physiological compensation, the animals respond with typical stress responses. It has previously been shown that Atlantic cod show stress responses when elevation of water temperature is faster than 1 degree/day, for this reason we chose hyperthermia as stress agent for this experiment.</p> <p>Findings</p> <p>We here describe the expression of eight candidate reference genes from Atlantic cod (<it>Gadus morhua l</it>.) and their stability during thermal stress (temperature elevation of one degree C/day for 5 days). The genes investigated were: Eukaryotic elongation factor 1 alpha, <it>ef1a</it>; 18s ribosomal RNA; <it>18s</it>, Ubiquitin conjugate protein; <it>ubiq</it>, cytoskeletal beta-actin; <it>actb</it>, major histcompatibility complex I; MHC-I light chain, beta-2 -microglobulin; <it>b2m</it>, cytoskeletal alpha-tubulin; <it>tba1c</it>, acidic ribosomal phosphoprotein; <it>rplp1</it>, glucose-6-phosphate dehydrogenase; <it>g6pd</it>. Their expression were analyzed in 6 tissues (liver, head kidney, intestine, spleen, heart and gills) from cods exposed to elevated temperature and compared to a control group. Although there were variations between tissues with respect to reference gene stability, four transcripts were more consistent than the others: <it>ubiq</it>, <it>ef1a</it>, <it>18s </it>and <it>rplp1</it>. We therefore used these to analyze the expression of stress related genes (heat shock proteins) induced during hyperthermia. We found that both transcripts were significantly upregulated in several tissues in fish exposed to increased temperature.</p> <p>Conclusion</p> <p>This is the first study comparing reference genes for RT-qPCR analyses of expression during hyperthermia in Atlantic cod. <it>ef1a, 18s, rplp1 </it>and <it>ubiq </it>transcripts were found to be well suited as reference genes during these experimental conditions.</p

    An evaluation of potential reference genes for stability of expression in two salmonid cell lines after infection with either Piscirickettsia salmonis or IPNV

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Due to the limited number of species specific antibodies against fish proteins, differential gene expression analyses are vital for the study of host immune responses. Quantitative real-time reverse transcription PCR (qRT-PCR) is one of the most powerful tools for this purpose. Nevertheless, the accuracy of the method will depend on the careful selection of genes whose expression are stable and can be used as internal controls for a particular experimental setting.</p> <p>Findings</p> <p>The expression stability of five commonly used housekeeping genes [beta-actin (<it>ACTB</it>), elongation factor 1-alpha (<it>EF1A</it>), ubiquitin (<it>UBQ</it>), glyceraldehyd-3-phosphate dehydrogenase (<it>GAPDH</it>) and tubulin alpha (<it>TUBA</it>)] were monitored in salmonid cell lines CHSE-214 and RTS11 after infection with two of the most fastidious fish pathogens, the facultative bacterium <it>Piscirickettsia salmonis </it>and the aquabirnavirus IPNV (Infectious Pancreatic Necrosis Virus). After geNorm analysis, <it>UBQ </it>and <it>EF1A </it>appeared as the most stable, although <it>EF1A </it>was slightly upregulated at late stages of <it>P. salmonis </it>infection in RTS11. <it>ACTB </it>instead, showed a good performance in each case, being always considered within the three most stable genes of the panel. In contrast, infection-dependent differential regulation of <it>GAPDH </it>and <it>TUBA </it>was also demonstrated.</p> <p>Conclusion</p> <p>Based on the data presented here with the cell culture models CHSE-214 and RTS11, we suggest the initial choice of <it>UBQ</it>, <it>ACTB </it>and <it>EF1A </it>as reference genes in qRT-PCR assays for studying the effect of <it>P. salmonis </it>and IPNV on the host immune response.</p
    • ā€¦
    corecore